Salta al contenuto principale
Passa alla visualizzazione normale.

FELICE PECORARO

Chimney and Periscope Grafts Observed Over 2 Years After Their Use to Revascularize 169 Renovisceral Branches in 77 Patients With Complex Aortic Aneurysms

  • Autori: Lachat M; Veith FJ; Pfammatter T; Glenck M; Bettex D; Mayer D; Rancic Z; Gloekler S; Pecoraro F
  • Anno di pubblicazione: 2013
  • Tipologia: Articolo in rivista (Articolo in rivista)
  • OA Link: http://hdl.handle.net/10447/99625

Abstract

Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch to visceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination was performed at 6 weeks; 3, 6, and 12 months; and annually thereafter. Results: Technical success was achieved in 76 (99%) patients; 1 branch stent-graft became dislocated from a renal artery, which could not be re-accessed. Overall, 169 target vessels (121 renal arteries, 30 superior mesenteric arteries, 17 celiac trunks, and 1 inferior mesenteric artery) were addressed with the chimney graft configuration in 111 and the periscope graft configuration in 58. In total, 228 devices were used for the CPGs: 213 Viabahn stent-grafts and 15 bare metal stents. Over a mean 25616 months (range 1–121), 9 patients died of unrelated causes. Nearly all (95%) of the patients demonstrated a decreased or stable aneurysm size on imaging; there was a mean 13% shrinkage in aneurysm diameter. Twenty patients had primary type I/III endoleaks at discharge; in follow-up, only 3 of these were still present (no secondary or recurrent endoleaks were noted). Additional endovascular maneuvers were required for CPG-related complications in 13 patients fromintervention throughout follow-up. Overall, 4 CPGs occluded (98% target vessel patency); no stent-graft migration was observed. Renal function remained stable in all patients. Conclusion: In this series, the use of CPGs has proven to be a feasible, safe, and effective way to treat thoracoabdominal and pararenal aneurysms with maintenance of blood flow to the renovisceral arteries. Nearly all of the aneurysms showed no increase in diameter over a .2- year mean follow-up, which supports the midterm adequacy of the CPG technique as a method to effectively revascularize branch vessels with few endoleaks or branch occlusions.