Salta al contenuto principale
Passa alla visualizzazione normale.

ANTONIO CATALIOTTI

A chirp-z transform-based synchronizer for power system measurements

  • Autori: AIELLO M; CATALIOTTI A; NUCCIO S
  • Anno di pubblicazione: 2005
  • Tipologia: Articolo in rivista (Articolo in rivista)
  • OA Link: http://hdl.handle.net/10447/3010

Abstract

In the last few years increased interest in power and voltage quality has forced international working groups to standardize testing and meas-urement techniques. IEC 61000-4-30, which defines the characteristics of instrumentation for the measurement of power quality, refers to IEC 61000-4-7 for the evaluation of harmonics and interharmonics. This standard, revised in 2002, requires a synchronous sampling of volt-age or current signal, in order to limit errors and to ensure reproducible results even in the presence of non-stationary signals. Therefore an accurate estimation of the fundamental frequency is required, even in the presence of disturbances. In this paper an algorithm to detect the fundamental frequency is proposed; it is based on the Chirp Z Transform (CZT) spectral analysis and is able to observe all standards in force because of its accuracy and working characteristics. Theoretical aspects are discussed and various experimental tests are reported, comparing the proposed method with a similar well-known one based on interpolated Fast Fourier Transform analysis. Finally, a complete characterization of the proposed system was performed and its accuracy was evaluated by means of a calibrator