The metrological characterization of the static meters for reactive energy in the presence of harmonic distortion

Abstract

For the electricity metering for billing purposes in distribution systems, the static meters are substituting the traditional inductive meters. Thus, the evaluation of the performances of such equipments is required, also in the presence of disturbances affecting the power systems. With respect to this, this paper analyzes the main aspects related to the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Particular attention is given to the reference standard meters, that are not considered by the actual in-force Standards. The analysis is supported by several experimental tests